How we calculate it
Each item's daily energy is watts times quantity times hours of use per day. Usable energy is the battery capacity times the usable share times inverter efficiency. Runtime is usable energy divided by the average draw (daily energy divided by 24 hours).
- Inverter efficiency, 85 percent by default: this is our planning assumption, not a measured number for any product. Check your model's manual and change it.
- Usable share, 100 percent by default: power station capacity ratings are usually the whole battery. Lower it if your manual says otherwise.
- Refrigerators and freezers cycle on and off, so we use their average draw, not the running watts. Take the kWh per year from the yellow EnergyGuide label and divide by 8.76. The defaults (50 W fridge, 30 W freezer) are examples only.
- Lights, chargers, router and laptop defaults are rough examples, not measurements. Use the watts printed on your devices or chargers.
- Pumps and furnace fans use Honda's running watts. Set the hours to how long they actually run in a day, which you may need to guess.
The output rating check warns you if everything on at once would exceed the station's continuous output. Motors also need a starting surge, so compare against the surge rating in the manual too.
Need to run more than a power station can? Size a generator with our generator size calculator, or see power station guides.
Frequently asked questions
How long will a power station run a refrigerator?
Divide the station’s usable watt-hours by the fridge’s average draw. A fridge rated at 450 kWh a year on its EnergyGuide label averages about 51 watts. A 1,000 Wh station at 85 percent inverter efficiency delivers about 850 Wh, or roughly 16 to 17 hours of that fridge alone. Older or larger fridges use more, and opening the door often shortens it.
How do I find my refrigerator’s average watts?
Find the estimated yearly electricity use in kWh on the yellow EnergyGuide label, or look the model up in the ENERGY STAR product finder. Divide that number by 8.76 to get average watts. For example, 400 kWh a year divided by 8.76 is about 46 watts.
Why is the runtime shorter than capacity divided by watts?
Power stations convert battery DC power to household AC through an inverter, which loses some energy as heat. This calculator assumes 85 percent efficiency by default. Running devices from the DC or USB ports skips the inverter and usually lasts longer.
Can a power station run a sump pump?
Only if its continuous output and surge rating cover the pump. Honda estimates a 1/3 HP sump pump at about 800 running watts and 1,300 watts to start. Because a sump pump runs in short bursts, runtime depends on how often it cycles, which depends on how much water is coming in.